Filtera is an Authorized Filtrete
Commercial Filtration Distributor
Freight:
SPECIAL! Only $1.00 shipping for each internet order. (within the Continental USA)
|
Filtrete™ Commercial High Performance Mini-Pleat HVAC Utility Filters provide a cost effective
filtration alternative - with the performance you’ve come to expect from 3M.
100% synthetic media - filters are durable, less chance of filter damage during handling and installation, resistant to moisture and common chemicals, resistant to fiber shedding.
Typical Applications
Filtrete™ Commercial High Performance HVAC Utility Filters are ideal for your:
• Commercial and office buildings.
• Educational institutions.
• Government facilities.
• Hotels and entertainment complexes.
Increase air flow / lower fan energy consumption for equivalent filter efficiency
Physical Characteristics
• 100% synthetic media - resists moisture and common chemicals
• 100% synthetic frame - lightweight, resists moisture
• High durability - no special handling required
• Continuous pleat spacing glue bead
• Electrostatically charged media
Performance Notes
• Typical initial resistance: 0.37 inches (0.94 cm) of water @ 492 fpm
• UL 900, Class 1 flammability rating (U.S.)
• UL 900, Class 2 flammability rating (Canada)
• Operating temperature range: 122°F (50°C), -22°F (-30°C)
Performance Data
• Air Velocity 492 fpm (1968 cfm for 24" x 24" filter)
• Initial Resistance 0.37 inches (0.94 cm) of water
• Recommended Final Resistance 1.40 inches (3.56 cm) of water
• Average Dust Spot Efficiency per ASHRAE 52.1-19921 90-95%
• Initial Efficiency Rating per ASHRAE 52.2-19991 MERV-14
• Minimum Efficiency Rating During Conditioning Corresponds to MERV-12
to Simulate Actual Use in Commercial Applications*
Efficiency During Use:
Particle capture efficiency of electrostatically charged filters has been shown to decrease during actual use. The timeframe and the extent to which this decrease occurs depend on particle size and loading conditions. This effect has been observed in as little as one week to six weeks of actual use. Actual particle efficiencies during use may be lower than those shown, also depending on particle size and loading conditions.
Service Life:
Filter should be replaced before reaching a final resistance of 1.40 inches (3.56 cm) of water to maintain design performance of the filter. Certain system designs may require filter replacement at lower resistances.
The low pressure drop feature of Filtrete Commercial High Performance HVAC Utility
Filters may help reduce fan energy consumption.
Durable synthetic media and construction
Media construction is resistant to moisture and common chemicals.
• Resilient construction.
• Resistant to fiber shedding.
• Unique, electrostatically-charged, open construction media.
Long filter life
The unique media and construction of Filtrete Commercial High Performance HVAC
Utility Filters may result in long filter life.
• Media loads through the depth of the filter, contributing to long filter life.
• Minipleat construction provides high surface area, contributing to long filter life.
Small package size
• Easy to handle.
• Low disposal volume.**
Demonstrated filtration efficiency
Filtrete Commercial High Performance HVAC Utility Filters have been tested by independent laboratories in accordance with ASHRAE 52.1-1992 and 52.2-1999 standards. Electret-based filter media is known to decrease in efficiency under many environmental conditions. To evaluate filter efficiency during actual use, additional testing to simulate in-use performance has been carried out. Refer to technical data sheet for detailed product attributes and performance.
Possible Fan Energy Cost Reductions
Use of Filtrete™ Commercial High Performance HVAC Utility Filters may help reduce fan energy costs due to their low airflow resistance relative to filters having comparable efficiency ratings and construction. When the air handling unit is cleaned, the savings may be even greater and may help to increase your return on initial investment.
3M Filtrete Commercial High Performance HVAC Utility Filter Literature:
3M Technical Data Sheet – 269k pdf file
3M Energy Saving Case Study – 152k pdf file
_____________________________________________________
* Performance ratings based on testing of new filters by an independent laboratory.
** Disposal of used filters must comply with applicable federal, state and local laws and regulations.
What is the (+P Code) in the item popdown menu?
Filtera puts the "A" in filter!
Call Filtera Toll-Free: (888) 933-0100
Monday - Friday 8:30 am to 5:00 pm central time |
|