A New Level of Respiratory Protection
• Enhanced protection against microbial threats
• Innovative antimicrobial technologies
The Triosyn® T-3000™ respirator provides front-line protection for police officers, homeland defense personnel, and other emergency and rescue responders against viral and bacterial threats with an advanced particulate barrier.
The T-3000™ disposable respirator utilizes the Triosyn proprietary T50 Powder. When microorganisms come in contact with the T-3000™ filtration media, the active ingredient in Triosyn T50 Powder penetrates the outer membrane of the microorganism, disrupting key cell functions so that it cannot function, grow or reproduce, thus ensuring consistent and reliable performance throughout the life of the product.
TRIOSYN® T-3000™
• NIOSH Approved P95 Particulate Respirator: TC-84A-4109
• Flatfold design allows for easy storage
• Each respirator is sealed in its own foil package with imprinted user instructions
KEY FEATURES FOR ALL TRIOSYN RESPIRATORS:
• Antimicrobial product protection
• Consistent and reliable performance
• Carbon layer for relief against nuisance levels of organic vapors
• Fluid-resistant outer layer
• Secure, comfortable fit with padding, adjustable nose bridge and low breathing resistance
WHAT IS TRIOSYN RESIN?
Triosyn® resin is a unique iodine preparation that harnesses the germicidal power of iodine. At the same time, Triosyn® resin is designed to precisely control the delivery and dosage of free molecular iodine to harmful microorganisms, which minimizes any toxic effects to humans and the environment. Extensive laboratory testing demonstrates that Triosyn® resin quickly and effectively inactivates a broad spectrum of microorganisms on contact.
Triosyn® resin is an extremely versatile antimicrobial agent with applications in drinking water disinfection, paints and coatings, air filtration products, and medical devices, just to name a few. The Triosyn® resin family of products includes Triosyn® T50 (EPA Reg. 72897-1) and Triosyn® T50 Powder (EPA Reg. 72897-2).
HOW DOES TRIOSYN WORK?
Triosyn® resin is produced by thermally fusing pure iodine crystals under high pressure with a specialized polymer. During this process, a stable electrochemical bond is formed between the iodine and the polymer, allowing no free release of iodine in the media employed. This electrochemical bond serves as a demand-release mechanism that allows iodine molecules to be released from Triosyn® resin in the presence of demand-causing microorganisms and in amounts required to eliminate the source of the demand. Triosyn® is activated by the strong ionic charge of surface proteins that cover microorganisms and then interacts with organisms through ionic transfer. Upon contact with a microorganism, ionic molecular iodine is transferred from Triosyn® resin, to the more strongly charged surface proteins of the microbe. The iodine immediately devitalizes the microorganism by removing electrons from the organism's surface proteins which are necessary for life and reproduction.
TRIOSYN T-3000 BROCHURES:
Triosyn T-3000 Brochure 1 – 278k pdf file
Triosyn T-3000 Brochure 2 – 174k pdf file
Triosyn T-3000 Brochure 3 – 445k pdf file
Triosyn T-3000 User Instructions – 119k pdf file
SOME USER TESTIMONIALS:
"My team and I need superior protection from a facemask against harmful biological agents and that is why we use the T-3000" - Deputy Sheriff
"When I go on a call, I have to be prepared for an array of viruses and bacteria. I know that theT-3000 offers unmatched respiratory protection from these and other unknowns and I never go on a call without it." - EMT from Atlanta
FREQUENTLY ASKED QUESTIONS
(as quoted from Triosyn literature)
Q: How do Triosyn® facemasks with Antimicrobial Product Protection differ from other disposable facemasks?
A:The Triosyn T-Series facemasks with Antimicrobial Product Protection trap potentially harmful airborne particulates just like traditional facemasks. The difference lies in the proven ability of the Triosyn T-3000™ facemask to trap biological agents throughout the life of the product. This is achieved through the antimicrobial action of Triosyn® T50 powder which protects the filtration media from microbial deterioration.
Q: What is the filtration efficiency of the Triosyn T-3000T™ facemask?
A:Triosyn T-3000™ facemasks are certified by NIOSH as having a 95% filtration efficiency for particles in the range of 0.3 micron. The T-3000™ is also labeled as a "P" level facemask meaning that it is "strongly resistant to oil". This rating is most useful if you are working in an environment where an oil mist may be present.
Q: The T-3000™ mask contains Iodine; has the T-3000™ mask been tested to determine possible hazards?
A: The Triosyn T-3000™ facemask contains Triosyn T-50 Powder as its active ingredient. Triosyn® T50 Powder is registered with the US Environmental Protection Agency (EPA Reg. No. 72897-2). Before issuing a product registration, the EPA requires and reviews extensive test data that demonstrate the product can be used without posing harm to human health and the environment. Most importantly, Triosyn Corp. establishes exacting safety and performance standards for all of its products before offering them for sale.
Q: The Triosyn T-3000™ is listed as "fluid resistant"; does this mean that the facemask is waterproof?
A: The T-3000™ facemask has a fluid resistant outer layer made of a non-absorbent polypropylene fiber. This does not mean that fluids will be repelled, but that the outer layer of the facemask could come into contact with fluids without a negative impact on the integrity of the materials.
Q: What is the shelf life of the facemask in its foil packaging and out?
A: In its original packaging, the Triosyn T-3000™ mask has a shelf life of 48 months from the date of manufacturing. Please check the product packaging for the original date of manufacture. Once the packaging has been opened, the mask can be used continuously for 8 hours. Please discard the facemask and replace with a new one after 8 hours.
USE INSTRUCTIONS:
1. Failure to follow all instructions and limitations concerning the use of the respirator and/or failure to wear the respirator for the whole duration of exposure to contaminants can seriously reduce the performance characteristics of the respirator and lead to illness, injury or death.
2. Before occupational use, the wearer must first be trained by the employer in the correct use of the respirator in accordance with applicable safety and health standards.
3. OSHA standards including 29CFR1910.134(e)(5) and CSA standard Z94.4-93 require that the wearer be fit-tested.
4. Discard the respirator and replace with a new one if:
- excessive clogging of the respirator causes breathing difficulty;
- the respirator becomes damaged.
Discard the respirator and replace with a new one after every use.
5. Leave the contaminated area if dizziness, irritation or other distress occurs.
USE LIMITATIONS:
1. Do NOT use the respirator or enter or stay in a contaminated area under the following circumstances:
- atmosphere contains less than 19.5% oxygen;
- if you smell or taste a contaminant;
- for protection against gases or vapors;
- contaminants or their concentrations are unknown or immediately dangerous to life or health;
- concentrations of contaminants exceed maximum use concentrations in applicable OSHA standards or applicable government regulations or 10 times the PEL (Permissible Exposure Limit whichever is lower;
- for sandblasting, paint-spray operations, asbestos.
2. Do NOT modify or misuse the respirator.
3. Do NOT use the respirator with beards or other facial hair that interferes with direct contact between the face and the edge of the respirator, or any other conditions that may prevent a good face-seal.
"P" Series respirators are replaced when the wearer senses an increase in breathing resistance due to the filters collecting particulate matter. Replace masks frequently.
PROTECTION:
- P-series filters: effective against all particulate aerosols.
- Carbon layer: removes nuisance levels of organic vapors (odor removal only).
Do NOT use:
- for protection against hazardous concentrations of gases or vapors;
- for sandblasting, paint-spray operations, asbestos.
BIOLOGICAL PARTICLES:
This respirator can help reduce inhalation exposures to certain airborne biological particles (e.g., mold, Bacillus anthracis, Mycobacterium tuberculosis, etc.) but it may not eliminate the risk of contracting infection, illness or disease. OSHA and other government agencies have not established safe exposure limits for these contaminants.
DONNING and FITTING INSTRUCTIONS:
Follow these instructions each time respirator is worn.
1. Remove respirator from package and "unfold".
2. Hold the respirator in the hand, allowing the head-straps to hang loosely in front of the mask.
3. Position the lower head strap around the neck below the ears. Hold the respirator against the face and place the top head-strap around the crown of the head.
4. Adjust head straps by grasping the locking slide and pull adjuster ring until respirator fits comfortably.
5. Fit the nose area to the shape of the face by forming the nose piece with the fingertips. Start from the top of the nose piece ', working downward while pressing against the nose. Always use both hands.
FIT-CHECK THE FACE-SEAL AS FOLLOWS:
- Place both hands over the respirator - do not disturb the position of the respirator.
- Exhale sharply to detect leakage.
WARNING:
- If you cannot achieve satisfactory fit, do NOT enter the contaminated area. See your Supervisor.
- This respirator helps protect against certain contaminants. It may not eliminate the risk of contracting disease or infection. Misuse may result in sickness or death.
S-SPECIAL OR CRITICAL USER'S INSTRUCTIONS:
This product contains iodine. Store in a cool, dry place out of direct sunlight. Some discoloration may occur during storage and use: discoloration will not affect the quality of the product. If any irritation occurs, discontinue use immediately and consult a physician. Do not use this product if you are allergic or sensitive to iodine, have a thyroid condition, or are pregnant.
FOR MORE INFORMATION or assistance, see your supervisor or contact Triosyn Corp at 1-866-865-5084. If outside of the United States, call 802-865-5084 (USA).
What is the (+P Code) in the item popdown menu?
Filtera puts the "A" in filter!
Call Filtera Toll-Free: (888) 933-0100
Monday - Friday 8:30 am to 5:00 pm central time |
|